!!! product phase-out !!! The preferred successor type is 3UG5512-1AR20 phase failure and sequence 3x160-690 V analog monitoring relay phase failure and sequence 3 x 160...690 V 50...60 Hz AC 1 changeover contact screw terminal Line monitoring relay SIRIUS 3UG4 for monitoring phase sequence, phase failure and phase asymmetry, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors or cranes. Worldwide use thanks to international certificates. Different versions enable application-related selection of products. Less space required in the control cabinet thanks to slim design. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. SIRIUS relays - one range for every application.
Relés Industriais
Monitoring relay, analog, phase failure and sequence 3x 160-690 V AC 50 to
Ref Nortécnica:
EAN:
4011209642249
Descrição
Informações Técnicas
Atributos
Largura
22.5
Altura
83
Profundidade
91
Faixa de medição de tensão
160
Com braçadeiras destacáveis
Sim
Monitorização de sequência de fases
Sim
Deteção de falha de fase
Sim
Função de deteção de subtensão
Não
Função de deteção de sobretensão
Não
Função de deteção de assimetria
Não
Acabamento da conexão elétrica
Ligação com parafuso
Tensão de alimentação de corrente nominal de 50 Hz AC
160
Tensão de alimentação de corrente nominal de 60 Hz CA
160
Tensão de alimentação de corrente nominal DC
-
Tempo de atraso máx. permitido de tempo na energização
-
Tempo de atraso min. ajustável de tempo na energização
-
Tempo de atraso da max. permitido
-
Tempo de atraso de min. ajustável
-
Tipo de tensão para atuação
EV000460
Número de contatos como contato normalmente fechado
0
Número de contatos como contato normalmente aberto
0
Número de contatos como inversores
1
Marcas
SIEMENS
Descrição Longa
!!! product phase-out !!! The preferred successor type is 3UG5512-1AR20 phase failure and sequence 3x160-690 V analog monitoring relay phase failure and sequence 3 x 160...690 V 50...60 Hz AC 1 changeover contact screw terminal Line monitoring relay SIRIUS 3UG4 for monitoring phase sequence, phase failure and phase asymmetry, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors or cranes.
Worldwide use thanks to international certificates. Different versions enable application-related selection of products. Less space required in the control cabinet thanks to slim design. All versions with removable terminals.
In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide.
The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays.
SIRIUS relays - one range for every application.