Orange Power cable 3m long for IEC Multi-fixing LED lamps


Power Cable <> = 1 kV, for Mobile Application
Orange Power cable 3m long for IEC Multi-fixing LED lamps
Manufacturer Ref:
NSYLAM3MN
Nortécnica Ref:
EAN:
3606489550868
Description
Technical Information
Attributes
Secção nominal do condutor
1.5
Material core insulation
Polyvinyl chloride (PVC)
Core identification
Colour
Peso
0.352
Drain wire
No
Tensão nominal U
500
Stranding element
No
Colour outer sheath
Orange
Shape of conductor
Round
Conductor material
Copper
Screen over stranding element
None
Screen over stranding
None
Material outer sheath
Polyvinyl chloride (PVC)
Conductor category
Class 5 = flexible
Armouringreinforcement
None
Permitted cable outer temperature during assemblinghandling
-16
65
Permitted cable outer temperature after assembling without vibration
-10
60
Torsion resistant
Yes
Número de elementos de fiação
-
Nominal cross section pilotreduced conductors
-
Number of pilotreduced conductors
-
Nominal voltage U0
300
Screen
No
Número de núcleos
3
Suspension element
None
Halogen free according to EN IEC 60754-2
Yes
Largura aproximada do cabo
8
Altura aproximada do cabo
0.7
Low smoke according to EN IEC 61034-2
Yes
Max. permitted conductor temperature
65
Protective barrier
Other
Diâmetro externo aprox.
3
With protective conductor
Yes
Oil resistant according to EN IEC 60811-404
Yes
Low temperature resistant according to EN 60811-504505506
Yes
Conductor surface
Bare
Reactiontofire according to EN 135016 Class
None
Reactiontofire according to EN 135016 Smoke production
None
Reactiontofire according to EN 135016 Flaming dropletsparticles
d0
Reactiontofire according to EN 135016 Acidity
None
AWG size
16
Nominal cross section conductor AWG
10
Nominal cross section pilotreduced conductors AWG
-
Raio mín. de curvatura permitido, aplicação móvel com orientação forçada
180
Raio mín. de curvatura permitido, aplicação móvelmovimento livre
90
Raio mín. de curvatura permitido, aplicação estáticainstalação permanente
45
Specification core insulation
Other
Specification material outer sheath
Other
Material armouring
Copper
Cable geometry
Round
Conductor resistance at 20 C
-
Core identification according to HD 308 S2
-
Tensão máxima de instalação
-
Flame retardant according to IEC 60332-1-2
Yes
Flame retardant according to IEC 60332-3-21 Cat A FR
Yes
Flame retardant according to IEC 60332-3-22 Cat A
No
Flame retardant according to IEC 60332-3-23 Cat B
Yes
Flame retardant according to IEC 60332-3-24 Cat C
Yes
Flame retardant according to IEC 60332-3-25 Cat D
Yes
Halogen free according to EN IEC 60754-1
Yes
Halogen free according to EN IEC 60754-3
Yes
Number of strands per conductor
-
Strand diameter
-
Brands
Schneider
Technical Sheet