Cabo MyHome para BUS - Bobina de 500 metros - Cinza
Power Cable <1 kV, for Permanent Installation
Cabo MyHome para BUS - Bobina de 500 metros - Cinza
Manufacturer Ref:
L4669/500
Nortécnica Ref:
03LL4669/500
EAN:
8012199654294
Description
Technical Information
Attributes
Nominal cross section conductor
0.35
Material core insulation
Polyvinyl chloride (PVC)
Core identification
Colour
Weight
-
Lead sheath
-
Drain wire
No
Nominal voltage U
500
Colour outer sheath
Grey
Shape of conductor
-
Diameter conductor
1.95
Conductor material
Copper
Material outer sheath
Polyvinyl chloride (PVC)
Conductor category
Class 2 = stranded
Armouringreinforcement
None
Permitted cable outer temperature during assemblinghandling
-15
70
Permitted cable outer temperature after assembling without vibration
-15
70
Nominal cross section pilotreduced conductors
-
Number of pilotreduced conductors
-
Core colour
-
Nominal voltage U0
300
Screen
No
Number of cores
2
Suitable for underground installation
-
Halogen free according to EN IEC 60754-2
-
Cable width approximate
-
Cable height approximate
-
Low smoke according to EN IEC 61034-2
No
Max. permitted conductor temperature
70
Protective barrier
None
Outer diameter approximate
5.5
With protective conductor
No
With rodent protection
-
Oil resistant according to EN IEC 60811-404
-
Low temperature resistant according to EN 60811-504505506
-
Conductor surface
-
Radial water blocking cable
-
Reaction-to-fire according to EN 13501-6 Class
-
Reaction-to-fire according to EN 13501-6 Smoke production
-
Reaction-to-fire according to EN 13501-6 Flaming dropletsparticles
-
Reaction-to-fire according to EN 13501-6 Acidity
-
AWG size
-
Nominal cross section conductor AWG
-
Nominal cross section pilotreduced conductors AWG
-
Min. permitted bending radius, stationary applicationpermanent installation
-
Specification core insulation
-
Specification material outer sheath
-
Twisted cores
-
Material armouring
-
Nominal equivalent cross section of reinforcement
-
Cable geometry
-
Conductor resistance at 20 C
-
Identificationcoding colour core
-
Core identification according to HD 308 S2
-
Suitable as installation cable
-
Certified for shipboard application
-
Certified as airport lighting cable
-
Max. tensile strength during installation
-
Circuit integrity according to EN 50200 annex E
-
Flame retardant according to IEC 60332-1-2
-
Flame retardant according to IEC 60332-3-21 Cat A FR
-
Flame retardant according to IEC 60332-3-22 Cat A
-
Flame retardant according to IEC 60332-3-23 Cat B
-
Flame retardant according to IEC 60332-3-24 Cat C
-
Flame retardant according to IEC 60332-3-25 Cat D
-
Halogen free according to EN IEC 60754-1
-
Halogen free according to EN IEC 60754-3
-
Circuit integrity according to IEC 60331-1
-
Circuit integrity according to IEC 60331-2
-
Circuit integrity according to IEC 60331-3
-
Circuit integrity according to EN 50200
-
Number of strands per conductor
-
Strand diameter
-
Insulation integrity according to DIN VDE 0472-814
-
Circuit integrity according to DIN 4102-12
-
Circuit integrity according to BS 6387 CWZ
-
Circuit integrity according to BS 8434-2
-
Circuit integrity according to BS 8491
-
Brands
Legrand