Power Cable <1 kV, for Permanent Installation

LXHIOZ1CBE 1X12016 183036 KV PT

Manufacturer Ref: 20305547
Nortécnica Ref:
EAN: 8434003203847
Description

LXHIOZ1CBE 1X12016 183036 KV PT

Technical Information
Attributes
Nominal cross section conductor
120
Material core insulation
Other
Core identification
Colour
Weight
1440
Flame retardant
EV004175
EF001024
-
Lead sheath
-
Drain wire
-
Circuit integrity
EV000494
Nominal voltage U
30
Colour outer sheath
Black
Shape of conductor
Round
Conductor material
Aluminium
Material outer sheath
Polyolefin
Conductor category
Class 2 stranded
Laminated sheath
-
Fibre optic elements
-
Permitted cable outer temperature during assemblinghandling
-25
70
Permitted cable outer temperature after assembling without vibration
-25
70
Number of pilotreduced conductors
0
Inner semi-conducting layer
Yes
Outer semi-conducting layer
Yes
Longitudinal water blocking screen
Yes
Nominal voltage U0
18
Screen
Yes
Number of cores
1
Longitudinal water blocking conductors
-
Nominal cross section concentric conductor
-
Halogen free according to EN IEC 60754-2
-
EF003793
EV000494
EF003794
-
Concentric conductor
None
Low smoke according to EN IEC 61034-2
-
Max. permitted conductor temperature
90
EF003805
0
Outer diameter approximate
39,4
With protective conductor
No
EF008027
-
Conductive coating
-
EF009769
-
EF009842
-
Conductor surface
Bare
Reaction-to-fire according to EN 13501-6 Class
Fca
Reaction-to-fire according to EN 13501-6 Smoke production
None
Reaction-to-fire according to EN 13501-6 Flaming dropletsparticles
None
Reaction-to-fire according to EN 13501-6 Acidity
None
AWG size
-
Nominal cross section conductor AWG
-
Min. permitted bending radius, stationary applicationpermanent installation
525
Specification core insulation
Crosslinked polyethylene XLPE
Specification material outer sheath
Polyethylene PE
Nominal equivalent cross section of reinforcement
-
Cable geometry
Round
Conductor resistance at 20 C
0,253
Core identification according to HD 308 S2
No
Suitable as installation cable
No
Certified for shipboard application
No
Suitable as medium-voltage cable
Yes
Suitable as high-voltage cable
No
Certified as airport lighting cable
No
Circuit integrity according to BS 6387 CWZ
No
EFUK0002
-
EFUK0003
No
Circuit integrity according to BS 8434-2
No
Circuit integrity according to BS 8491
-
EFUK0006
-
EFUK0007
No
EFUK0008
No
EFUK0009
No
EFUK0010
No
EFUK0011
No
EFUK0012
No
EFUK0013
No
EFUK0014
Yes
EFUK0015
Yes
EFUK0016
No
Brands
General Cable
Technical Sheet