Controlador M221-40IO transistor NPN ETHERNET
Programmable Logic Controllers and Dialogue Terminals
Controlador M221-40IO transistor NPN ETHERNET
Manufacturer Ref:
TM221CE40U
Nortécnica Ref:
EAN:
3606485408644
Description
Technical Information
Attributes
Width
163
Model
Compact
Height
103.6
Depth
75.9
With display
No
Suitable for safety functions
No
Number of digital inputs
24
Number of digital outputs
16
Number of analogue inputs
2
Number of analogue outputs
0
Voltage type supply voltage
DC
Type of memory
RAM
Memory size
512
Processing time 1K, binary operation
0.2
Supporting protocol for LON
No
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
With optical interface
No
Additional program memory possible
Yes
Supporting protocol for TCPIP
Yes
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
No
Redundancy
No
Suitable for rail mounting
Yes
Explosion safety category for gas
None
Explosion safety category for dust
None
System accessory
No
Appendant operation agent Ex ia
No
Appendant operation agent Ex ib
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Number of interfaces PROFINET
0
Number of HW-interfaces wireless
0
Front built-in possible
No
Rack-assembly possible
No
Wall mountingdirect mounting
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
IO link master
No
Number of relay outputs
0
Max. number of time switches
255
Performance level according to EN ISO 13849-1
None
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNetIP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supply voltage AC 50 Hz
-
-
Supply voltage AC 60 Hz
-
-
Supply voltage DC
19.2
28.8
Radio standard GPRS
No
Radio standard GSM
No
Mobile communications standard 3G UMTS
No
EF009547
No
SIL according to IEC 61508
None
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for DNP3
No
Supporting protocol for IEC 60870
No
Supporting protocol for EtherCAT
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A acetylene
No
Certified for UL hazardous location group B hydrogen
No
Certified for UL hazardous location group C ethylene
No
Certified for UL hazardous location group D propane
No
Certified for UL hazardous location group E metal dusts
No
Certified for UL hazardous location group F carbonaceous dusts
No
Certified for UL hazardous location group G non-conductive dusts
No
Brands
Schneider
Technical Sheet