Controlador M241 24 ES Transistor NPN
SCHNEIDER

Programmable Logic Controllers and Dialogue Terminals

Controlador M241 24 ES Transistor NPN

Nortécnica Ref:
EAN: 3606480611131

Description

Controlador M241 24 ES Transistor NPN

Technical Information

Attributes
Largura
150
Model
Compact
Altura
90
Profundidade
95
With display
No
Suitable for safety functions
No
Número de entradas digitais
14
Número de saídas digitais
10
Número de entradas analógicas
0
Número de saídas analógicas
0
Voltage type supply voltage
DC
Type of memory
NVRAM
Memory size
64000
Processing time 1K, binary operation
0.022
Supporting protocol for LON
No
Número de interfaces industriais HW Ethernet industrial
0
Número de interfaces HW RS-232
2
Número de interfaces HW RS-422
0
Número de interfaces HW RS-485
2
Número de interfaces HW USB
1
Número de interfaces HW paralelas
0
Número de interfaces HW outras
0
With optical interface
No
Additional program memory possible
Yes
Supporting protocol for TCPIP
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
No
Redundancy
No
Suitable for rail mounting
Yes
Explosion safety category for gas
None
Explosion safety category for dust
None
System accessory
No
Appendant operation agent Ex ia
No
Appendant operation agent Ex ib
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Número de interfaces PROFINET
0
Número de interfaces HW sem fio
0
Front built-in possible
No
Rack-assembly possible
No
Wall mountingdirect mounting
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
IO link master
No
Number of relay outputs
0
Max. number of time switches
0
Performance level according to EN ISO 138491
None
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNetIP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supply voltage AC 50 Hz
-
-
Supply voltage AC 60 Hz
-
-
Supply voltage DC
19.2
28.8
Mobile communication standard GPRS
No
Mobile communication standard 2G GSM
No
Mobile communication standard 3G UMTS
No
EF009547
No
SIL according to IEC 61508
None
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for DNP3
No
Supporting protocol for IEC 60870
No
Supporting protocol for EtherCAT
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A acetylene
No
Certified for UL hazardous location group B hydrogen
No
Certified for UL hazardous location group C ethylene
No
Certified for UL hazardous location group D propane
No
Certified for UL hazardous location group E metal dusts
No
Certified for UL hazardous location group F carbonaceous dusts
No
Certified for UL hazardous location group G non-conductive dusts
No
Brands
SCHNEIDER