SINAMICS G120D Control Unit CU240D-2 PN-F FO PROFINET and Safety Integrated via fiber-optic cable in push-pull version 6 DI/3 F-DI, 2 DO/1 F-DO, 2 AI HTL encoder interface Degree of protection IP65 Ambient temperature 0 to +45 °C without Power Module SINAMICS CU240D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. The CU240D‑2 Control Units supersede the CU240D Control Units, whereby both versions can be operated with PM250D Power Modules. The Control Units are available in different versions, for example, in CU240D-2 DP, CU240D-2 DP-F, CU240D-2 PN, CU240D-2 PN-F, CU240D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU240D-2 PN-F FO (Fiber Optic). The safety function Safe Torque Off (STO) is already integrated into the standard versions of the CU240D‑2 series (CU240D‑2 DP and CU240D‑2 PN). It can be activated either via PROFIsafe or via the safety input. With the fail-safe variants of the CU240D‑2 series (CU240D‑2 DP‑F xx and CU240D‑2 PN‑F xx), the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS – the integrated drive family for every field of application.

Technical Information

Attributes
Width
153
Height
208
Depth
118
With control element
-
Number of digital inputs
6
Number of digital outputs
2
Number of analogue inputs
2
Number of analogue outputs
-
Supporting protocol for LON
No
Número de interfaces industriais HW Ethernet industrial
2
Número de interfaces HW RS-232
0
Número de interfaces HW RS-422
0
Número de interfaces HW RS-485
0
Número de interfaces HW de série TTY
0
Número de interfaces HW USB
0
Número de interfaces HW paralelas
11
Número de interfaces HW outras
0
With optical interface
Yes
Supporting protocol for TCPIP
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
No
Degree of protection IP
IP65
With PC connection
Yes
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Mains voltage
-
Mains frequency
-
4-quadrant operation possible
-
Número de interfaces PROFINET
2
Type of converter
-
Number of phases output
-
Number of phases input
-
Integrated breaking resistance
-
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
No
Max. output frequency
-
Max. output at linear load at rated output voltage
-
Max. output at quadratic load at rated output voltage
-
Relative symmetric net voltage tolerance
-
Relative symmetric net frequency tolerance
-
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNetIP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFIsafe
Yes
Supporting protocol for SafetyBUS p
No
Max. output voltage
-
Nominal output current I2N
-
Supporting protocol for BACnet
-
Degree of protection NEMA
-
Brands
SIEMENS
Descrição Longa
SINAMICS G120D Control Unit CU240D-2 PN-F FO PROFINET and Safety Integrated via fiber-optic cable in push-pull version 6 DI/3 F-DI, 2 DO/1 F-DO, 2 AI HTL encoder interface Degree of protection IP65 Ambient temperature 0 to +45 °C without Power Module SINAMICS CU240D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. The CU240D‑2 Control Units supersede the CU240D Control Units, whereby both versions can be operated with PM250D Power Modules. The Control Units are available in different versions, for example, in CU240D-2 DP, CU240D-2 DP-F, CU240D-2 PN, CU240D-2 PN-F, CU240D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU240D-2 PN-F FO (Fiber Optic). The safety function Safe Torque Off (STO) is already integrated into the standard versions of the CU240D‑2 series (CU240D‑2 DP and CU240D‑2 PN). It can be activated either via PROFIsafe or via the safety input. With the fail-safe variants of the CU240D‑2 series (CU240D‑2 DP‑F xx and CU240D‑2 PN‑F xx), the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS – the integrated drive family for every field of application.