SINAMICS G120D Control Unit CU250D-2 PN-F FO PROFINET via fiber-optic cable and Safety Integrated in push-pull version with positioning capability (EPOS) 6 DI/3 F-DI, 2 DQ/1 F-DQ HTL and SSI encoder interface Degree of protection IP65 Ambient temperature 0 to +45 °C Without Power Module SINAMICS CU250D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. CU250D‑2 Control Units can be used to implement applications with positioning requirements in the drive. This expansion opens up their use in lifting, swiveling, traversing or rotating applications. The positioning functionality is comparable to that of SINAMICS S110 servo drives. However, the following notes must be observed in this context: On the one hand, vector control and sensorless vector control are supported, on the other hand, positioning is possible via one encoder or in parallel using two encoders. The Control Units are available in different versions, for example, in CU250D-2 DP-F, CU250D-2 PN-F, CU250D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU250D-2 PN-F FO (Fiber Optic). With the fail-safe variants of the CU250D-2 series, the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS – the integrated drive family for every field of application.
Speed Variation and Motor Starting
SINAMICS G120D CU250D-2 PN-F FO
Nortécnica Ref:
EAN:
4042948697030
Description
Technical Information
Attributes
Largura
153
Altura
208
Profundidade
118
With control element
-
Número de entradas digitais
6
Número de saídas digitais
2
Número de entradas analógicas
0
Número de saídas analógicas
-
Supporting protocol for LON
No
Número de interfaces industriais HW Ethernet industrial
2
Número de interfaces HW RS-232
0
Número de interfaces HW RS-422
0
Número de interfaces HW RS-485
0
Número de interfaces HW de série TTY
0
Número de interfaces HW USB
0
Número de interfaces HW paralelas
10
Número de interfaces HW outras
0
With optical interface
Yes
Supporting protocol for TCPIP
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
No
Degree of protection IP
IP65
With PC connection
Yes
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Mains voltage
-
Mains frequency
-
4-quadrant operation possible
-
Número de interfaces PROFINET
2
Type of converter
-
Number of phases output
-
Number of phases input
-
Integrated breaking resistance
-
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
No
Max. output frequency
-
Max. output at linear load at rated output voltage
-
Max. output at quadratic load at rated output voltage
-
Relative symmetric net voltage tolerance
-
Relative symmetric net frequency tolerance
-
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNetIP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFIsafe
Yes
Supporting protocol for SafetyBUS p
No
Max. output voltage
-
Nominal output current I2N
-
Supporting protocol for BACnet
-
Degree of protection NEMA
-
Brands
SIEMENS
Descrição Longa
SINAMICS G120D Control Unit CU250D-2 PN-F FO PROFINET via fiber-optic cable and Safety Integrated in push-pull version with positioning capability (EPOS) 6 DI/3 F-DI, 2 DQ/1 F-DQ HTL and SSI encoder interface Degree of protection IP65 Ambient temperature 0 to +45 °C Without Power Module SINAMICS CU250D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. CU250D‑2 Control Units can be used to implement applications with positioning requirements in the drive. This expansion opens up their use in lifting, swiveling, traversing or rotating applications. The positioning functionality is comparable to that of SINAMICS S110 servo drives. However, the following notes must be observed in this context: On the one hand, vector control and sensorless vector control are supported, on the other hand, positioning is possible via one encoder or in parallel using two encoders. The Control Units are available in different versions, for example, in CU250D-2 DP-F, CU250D-2 PN-F, CU250D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU250D-2 PN-F FO (Fiber Optic). With the fail-safe variants of the CU250D-2 series, the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS – the integrated drive family for every field of application.